5A High Precision Grid Ground Network Earth Soil Resistance Tester

Product Details
Customization: Available
After-sales Service: 24-Hour Online Service
Warranty: One Year
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (21)
  • 5A High Precision Grid Ground Network Earth Soil Resistance Tester
  • 5A High Precision Grid Ground Network Earth Soil Resistance Tester
  • 5A High Precision Grid Ground Network Earth Soil Resistance Tester
  • 5A High Precision Grid Ground Network Earth Soil Resistance Tester
  • 5A High Precision Grid Ground Network Earth Soil Resistance Tester
Find Similar Products
  • Overview
  • Product Description
  • Product Features
  • Detailed Photos
  • Technical Parameters
  • Product Dimension
  • Company Profile
  • Similar Recommendation
  • FAQ
Overview

Basic Info.

Model NO.
HZDW-F
Display Type
Digital Only
Certification
CE
Customized
Customized
Model No.
Hzdw-F
Power Supply
AC180~270V,.50/60Hz
Display
LCD
Instrument Weight
18kg
Output Current
5A
Max Output Voltage
400V
Place of Origin
Wuhan China
Gross Weight
25kg
Test Range
0~5000
Delivery Time
7 Days
Function
Earth Leakage Testing
Testing Frequency
45Hz and 50Hz
Load Method
Static Load
Control
Manual Control
Working Temperature
-10 to 55 Degree
Transport Package
Wooden Box with Foam
Specification
355*335*340mm
Trademark
HZRTZ POWER
Origin
Wuhan, China
HS Code
9030339000
Production Capacity
500sets/Month

Packaging & Delivery

Package Size
80.00cm * 70.00cm * 65.00cm
Package Gross Weight
25.000kg

Product Description

Product Description

This specialized instrument is used for measuring the grounding resistance of ground grids and the grounding continuity between grounding points.
It adopts frequency conversion anti-interference technology,does not require large current measurements,and can obtain accurate 50Hz data even in environments with strong interference,such as substations.Measurement results are displayed on a large LCD screen and can be printed outusing the built-in micro printer.The instrument can simultaneously measure grounding impedance and grounding resistance,providing a more accurate reflection of the actual characteristics of the ground grid.

Product Features

1. Good power frequency equivalence

2. Strong anti-interference capability

3. High precision.The basic error is only 0.005Ω

4. Can measure the grounding resistance of current piles,voltage piles,ground grids,continuity resistance and resistance,and soil resistivity.When used with the dedicated frequency selective voltmeter,it can measure step voltage,transfer potential,and contact voltage with higher anti-interference capability and accuracy

5. Full English menu operation,directly displaying measurement results.

6.  Low wiring labor:No need for large current lines.

Detailed Photos

5A High Precision Grid Ground Network Earth Soil Resistance Tester

Technical Parameters

I. Main Unit Technical Parameters:
1. Impedance Measurement Range:0~50000 Resolution:0.001mΩ
2. Measurement error:±(reading×2%+0.005Ω)
3. Test Current Waveform:Sine wave
4. Test Current Frequency:45,50,55,60,65Hz
5. Single frequency:45/55Hz,55/65Hz,47.5/52.5Hz automatic dual frequency
6. Output Current:1,2,3,4,5A;Maximum Output Voltage:450V
7. Measurement Line Requirements:Current line copper core cross-sectional area≥1.5mm²,Voltage line copper core cross-sectional area≥1.0mm²
8. Power Supply:AC180~270V,.50/60Hz


II. Frequency Selective Voltmeter Technical Parameters:
The frequency selective voltmeter can only be used with the large ground grid earth resistance tester
for anti-interference measurements of ground surface potential gradient,step voltage,and contact
voltage difference.

III. Main Technical Parameters:
Measurement Range:0-600V Accuracy:±Reading*1%+0.1mA Maximum Resolution: 0.001mV
Input Impedance:>500kΩ Human Body Simulation Resistance:1500Ω±5%
Measurement Frequency:Corresponds to the ground grid earth resistance tester,interference
suppression ratio:≥80dB
Working Time:about 8 hours Charging Time:about 3 hours
Power supply:220V±10%,50Hz/60Hz
Weight:18kg

    Product Dimension


    5A High Precision Grid Ground Network Earth Soil Resistance Tester5A High Precision Grid Ground Network Earth Soil Resistance Tester

    Company Profile

    5A High Precision Grid Ground Network Earth Soil Resistance Tester5A High Precision Grid Ground Network Earth Soil Resistance Tester5A High Precision Grid Ground Network Earth Soil Resistance Tester5A High Precision Grid Ground Network Earth Soil Resistance Tester5A High Precision Grid Ground Network Earth Soil Resistance Tester5A High Precision Grid Ground Network Earth Soil Resistance Tester

    Similar Recommendation

    5A High Precision Grid Ground Network Earth Soil Resistance Tester5A High Precision Grid Ground Network Earth Soil Resistance Tester5A High Precision Grid Ground Network Earth Soil Resistance Tester5A High Precision Grid Ground Network Earth Soil Resistance Tester5A High Precision Grid Ground Network Earth Soil Resistance Tester5A High Precision Grid Ground Network Earth Soil Resistance Tester5A High Precision Grid Ground Network Earth Soil Resistance Tester5A High Precision Grid Ground Network Earth Soil Resistance Tester

    FAQ

    Q1:Is your company a sales or a manufacturer? 
    We are an integrated trade and manufacturing company with our own factory. 

    Q2:If we need to customize our own brand or if there are special requirements for the built-in software of the machine, can it be customized?
    Yes, we accept OEM/ODM/OBM and can customize the built-in software of the product according to the customer's special requirements.

    Q3:What is the usual lead time? How long can we receive the order after placing it?
    In normal circumstances, products in stock can be received within 5 to 7 days via the fastest international express. Other situations may vary depending on the quantity of products ordered, whether there are special customization requirements, and the delivery time chosen.

    Q4:How can we ensure that the product will not be damaged during transportation, considering the large size of the product?
    We have professional internal and external packaging to ensure the safety and stability of the products during transportation. For fragile or other special parts, we will include an extra set to ensure that the customer can use the product immediately upon receipt.

    Q5:How do you handle after-sales service? What if there is a quality problem with the product or if the customer does not know how to operate it? 
    For quality issues that are not caused by human error, we provide a one-year warranty from the time the product is delivered, and lifetime technical support. Other after-sales issues will be addressed by our professional technical staff within 24 hours. The product comes with a user manual and an operation video.

    Send your message to this supplier

    *From:
    *To:
    *Message:

    Enter between 20 to 4,000 characters.

    This is not what you are looking for? Post a Sourcing Request Now
    Contact Supplier