10A No Load Current and Loss High Accuracy Transformer Capacity Tester

Product Details
Customization: Available
After-sales Service: 24-Hour Online Service
Warranty: One Year
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (21)
  • 10A No Load Current and Loss High Accuracy Transformer Capacity Tester
  • 10A No Load Current and Loss High Accuracy Transformer Capacity Tester
  • 10A No Load Current and Loss High Accuracy Transformer Capacity Tester
  • 10A No Load Current and Loss High Accuracy Transformer Capacity Tester
  • 10A No Load Current and Loss High Accuracy Transformer Capacity Tester
  • 10A No Load Current and Loss High Accuracy Transformer Capacity Tester
Find Similar Products
  • Overview
  • Product Description
  • Product Features
  • Detailed Photos
  • Technical Parameters
  • Product Dimension
  • Company Profile
  • Similar Recommendation
  • FAQ
Overview

Basic Info.

Model NO.
HZBTC-IV
Certification
CE
Customized
Customized
Model No.
Hzbtc-IV
Weight
3.9kg
Operating Temperature
-20ºC~60ºC
Power Supply
AC260V~265V
Voltage Testing Range with Power Source
0~10V
Voltage Testing Range No Power Source
0~750V
Currency Range with Power
0~10A
Currency Range Without Power
0~5A~100 Internal Dual Range
Control
Manual Control
Accuracy Grade
0.5
Features
High Precision, Convenient, Lightweight
Function
No Load Currency Testing, No Load Loss Test
Place of Origin
Wuhan China
Gross Weight
14kg
Delivery Time
7 Days
Transport Package
Wooden Box with Foam
Specification
320*240*130mm
Trademark
HZRTZ POWER
Origin
Wuhan, China
HS Code
9030899090
Production Capacity
500sets/Month

Packaging & Delivery

Package Size
51.00cm * 42.00cm * 33.50cm
Package Gross Weight
14.000kg

Product Description

Product Description

Transformer capacity characterization tester is upgraded by our R&D staff on the basis of theoriginal Division I transformer capacity tester.Continuing the original instrument's compact size,simple operation,easy to use and other advantages,and comprehensively upgraded the internalprocessor,data acquisition system,the national standard data,so that the instrument can be used ina wider range of higher test precision.

Transformer capacity characteristic tester,including transformer capacity,transformer no-loadloss,transformer load loss and its code level determination,electric parameter measurement andother functions.The instrument has its own internal high-efficiency rechargeable battery,which canwork without external power supply.The battery can be fully recharged for more than 200 consecutive transformer measurements.In addition,the instrument can provide three-phaseprecision 50Hz sine wave AC test power supply,in the measurement of transformer capacity andtransformer load loss does not require external three-phase test power supply and regulator,booster and other auxiliary equipment,thus greatly improving your work efficiency.

This product has many advantages such as small size,light weight,high measurement accuracy,good stability,simple operation and so on.It can completely replace the previous method ofmeasuring transformer loss and capacity by multi-meter method,with simpler wiring,moreconvenient testing and recording,which makes your work efficiency greatly improved.

Product Features

1. Adopting ARM+FPGA+ADC mode with RT-Thread real-time operating system,the instrument system is more robust and the measurement accuracy is higher.

2. 7-inch color high brightness LCD,icon touch interface, full English menu.

3. With perfect electronic help,each operation has wiringdiagram and text description,operation is intuitive andsimple.

4. Built-in large-capacity memory,can store 1000 groupsof test data.USB port communication,field test data canbesaved,according to customer needscan be uploaded to the PC data.

5. Integrates mainstream wired(RS232)and wireless communication(Bluetooth,WIFI)functions foreasy data upload and remote control.

6. With program remote upgrade function,according to customer requirements can be remotelyupgraded instrument program.

7. The real-time voltage channel and current channel waveform display can be observed under eachtest interface.

8. Real-time display of voltage,current,frequency,power factor,active power,reactive power andapparent power of the test circuit through a single interface,so as to facilitate the judgment of fieldwiring.

9. All test results are automatically corrected.You only need to enter the relevant parameters (such astemperature,no-load correction factor,etc.),so that the test results are more accurate.

10. Transformer characteristics measurement,the maximum range of voltage up to 1000V,themaximum range of current up to 100A,and is equipped with internal protection circuit.do not have to worry about the wrong gear selection and burn the instrument.

11. Transformer characteristics test,voltage,current range can be very flexible,easy to expand,simplythrough the external voltage transformer,current transformer can be,greatly widening theinstrument's test range.

Detailed Photos

10A No Load Current and Loss High Accuracy Transformer Capacity Tester

Technical Parameters

1. Built-in power supply output range
     Voltage:O to 10V
     Current:0~10A

2. Characteristic channel test rangeand accuracy
     Voltage range:AC1000V.Accuracy,±0.2%(F.S)±1 digital.
     Current range:AC 100A.Accuracy,±0.2%(F.S)±1 digital

3. Power and other indicators of measurement accuracy
    Power:±0.5%(F.S)(0.1≤Cosφ≤1)
               ±1.0%(F.S)(0.02≤Cosφ≤0.1)
    Measurement of no-load(negative)loss:±2%(0.1≤Cosφ≤1)

4. Transformer capacity test range:  6.3~125,000kVA

5. Operating Temperature:-20ºC~+60ºC

6. Charger power requirements:utility AC160V~265V

7. Insulation degree
    Capacity testing,voltage,current input point to the chassis insulation resistance ≥100MQ
    Charging power input to the chassis withstand industrial frequency 2kV(RMS),test duration of 1 minute

8. Main unit Dimension:32cm×24cm×13cm

9. Weight:4kg(Main unit)

Product Dimension

10A No Load Current and Loss High Accuracy Transformer Capacity Tester

Company Profile

10A No Load Current and Loss High Accuracy Transformer Capacity Tester
10A No Load Current and Loss High Accuracy Transformer Capacity Tester
10A No Load Current and Loss High Accuracy Transformer Capacity Tester


10A No Load Current and Loss High Accuracy Transformer Capacity Tester10A No Load Current and Loss High Accuracy Transformer Capacity Tester10A No Load Current and Loss High Accuracy Transformer Capacity Tester10A No Load Current and Loss High Accuracy Transformer Capacity Tester

Similar Recommendation

10A No Load Current and Loss High Accuracy Transformer Capacity Tester10A No Load Current and Loss High Accuracy Transformer Capacity Tester10A No Load Current and Loss High Accuracy Transformer Capacity Tester10A No Load Current and Loss High Accuracy Transformer Capacity Tester10A No Load Current and Loss High Accuracy Transformer Capacity Tester10A No Load Current and Loss High Accuracy Transformer Capacity Tester10A No Load Current and Loss High Accuracy Transformer Capacity Tester10A No Load Current and Loss High Accuracy Transformer Capacity Tester

FAQ

Q1:Is your company a sales or a manufacturer? 
We are an integrated trade and manufacturing company with our own factory. 

Q2:If we need to customize our own brand or if there are special requirements for the built-in software of the machine, can it be customized?
Yes, we accept OEM/ODM/OBM and can customize the built-in software of the product according to the customer's special requirements.

Q3:What is the usual lead time? How long can we receive the order after placing it?
In normal circumstances, products in stock can be received within 5 to 7 days via the fastest international express. Other situations may vary depending on the quantity of products ordered, whether there are special customization requirements, and the delivery time chosen.

Q4:How can we ensure that the product will not be damaged during transportation, considering the large size of the product?
We have professional internal and external packaging to ensure the safety and stability of the products during transportation. For fragile or other special parts, we will include an extra set to ensure that the customer can use the product immediately upon receipt.

Q5:How do you handle after-sales service? What if there is a quality problem with the product or if the customer does not know how to operate it? 
For quality issues that are not caused by human error, we provide a one-year warranty from the time the product is delivered, and lifetime technical support. Other after-sales issues will be addressed by our professional technical staff within 24 hours. The product comes with a user manual and an operation video.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier